The Smart Device Compare comparison

Aeotec Home Energy Meter 8 vs Shelly Pro EM-50

Understand the differences. Decide what matters to your home.

Build another comparison →

Before you compare every specification

Key differences between Aeotec Home Energy Meter 8 and Shelly Pro EM-50

A summary of selected recorded differences between these energy monitors. Check the full specification table below for details and conditions.

Feature differences among your selected devices
  • 2.4 GHz Wi-Fi (connectivity): Aeotec Home Energy Meter 8 — No; Shelly Pro EM-50 — Yes.
  • Bluetooth (connectivity): Aeotec Home Energy Meter 8 — No; Shelly Pro EM-50 — Yes (Bluetooth 4.2, also works as a Bluetooth gateway).
  • Ethernet (connectivity): Aeotec Home Energy Meter 8 — No; Shelly Pro EM-50 — Yes.
  • Load Management (features): Aeotec Home Energy Meter 8 — No; Shelly Pro EM-50 — Yes (Configurable load control to divert surplus PV production).
Specifications to check side by side
  • Other (connectivity): Aeotec Home Energy Meter 8 — No; Shelly Pro EM-50 — Modbus.
  • Z Wave (connectivity): Aeotec Home Energy Meter 8 — Z-Wave Hub required (Z-Wave 800 series with Long Range, S2 security, also acts as a repeater); Shelly Pro EM-50 — No.
  • Power Supply (installation): Aeotec Home Energy Meter 8 — Mains (120 V); Shelly Pro EM-50 — Mains (100-260 V).
  • Accuracy (metering): Aeotec Home Energy Meter 8 — 99% (Better than 99% above 0.05 A); Shelly Pro EM-50 — ±1% (Accuracy Class B for active energy, ±1% from 5 A to 50 A).
Information still to confirm
  • 8 of 39 comparison fields lack a resolved value for at least one selected device. Missing information is not evidence that a feature is absent.
  • Check the full table and manufacturer documentation before ruling out a device.

These observations are derived from recorded catalog data and have not all been independently verified. Confirm details with the manufacturer before purchasing.

Compare capabilities, compatibility and setup requirements.

What the catalog tells us

Understand the tradeoffs.

These counts describe the available data, not a quality score. More features do not automatically make a better device.

16differences with recorded values for every device
8rows with missing or unspecified information

Your priorities, side by side

Focus on what changes.

Mark the specifications you care about. Open manufacturer sources for verification scope; fields without citations remain catalog data. Expand notes for other qualifications.

Showing 39 of 39 rows. “Not recorded” does not mean “No”.

Connectivity

Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
No
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Catalog note

Bluetooth 4.2, also works as a Bluetooth gateway

Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Modbus
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
No
Aeotec Home Energy Meter 8
Z-Wave Hub required
Catalog note

Z-Wave 800 series with Long Range, S2 security, also acts as a repeater

Shelly Pro EM-50
No
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
No

Data Monitoring

Aeotec Home Energy Meter 8
Not applicable / unspecified
Shelly Pro EM-50
Yes
Catalog note

CSV export of the consumption chart

Aeotec Home Energy Meter 8
Not applicable / unspecified
Shelly Pro EM-50
60 days
Catalog note

At least 60 days of 1-minute data stored on the device

Aeotec Home Energy Meter 8
Not applicable / unspecified
Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
Not recorded
Shelly Pro EM-50
Not recorded
Aeotec Home Energy Meter 8
Not applicable / unspecified
Shelly Pro EM-50
Yes
Catalog note

Cost periods and tariff distribution in the Shelly Smart Control app

Aeotec Home Energy Meter 8
Not applicable / unspecified
Shelly Pro EM-50
Yes

Features

Aeotec Home Energy Meter 8
Yes
Catalog note

Through the Z-Wave hub, not the device itself

Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Catalog note

Configurable load control to divert surplus PV production

Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Catalog note

Integrated switch with potential-free contacts, 2 A at 240 V

Installation

Aeotec Home Energy Meter 8
Yes
Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Catalog note

One DIN module wide

Aeotec Home Energy Meter 8
Mains (120 V)
Shelly Pro EM-50
Mains (100-260 V)
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
No

Integrations

Aeotec Home Energy Meter 8
No
Catalog note

Alexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish

Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
No
Aeotec Home Energy Meter 8
Not recorded
Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
Yes
Catalog note

Via the Z-Wave JS integration

Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
No
Aeotec Home Energy Meter 8
Yes
Shelly Pro EM-50
Yes
Catalog note

Via the official Shelly Cloud integration

Local Control

Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Catalog note

RPC over HTTPS and WebSocket, UDP, webhooks, scripting and Modbus TCP

Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes
Aeotec Home Energy Meter 8
No
Shelly Pro EM-50
Yes

Metering

Aeotec Home Energy Meter 8
99%
Catalog note

Better than 99% above 0.05 A

Shelly Pro EM-50
±1%
Catalog note

Accuracy Class B for active energy, ±1% from 5 A to 50 A

Aeotec Home Energy Meter 8
Yes
Shelly Pro EM-50
Yes
Catalog note

4 quadrant measurement with a returned energy counter

Aeotec Home Energy Meter 8
Not applicable / unspecified
Shelly Pro EM-50
Not applicable / unspecified
Aeotec Home Energy Meter 8
2
Catalog note

2 x 200 A clamps for the service mains

Shelly Pro EM-50
2
Catalog note

2 x 50 A current transformers

Aeotec Home Energy Meter 8
200 A
Shelly Pro EM-50
50 A
Aeotec Home Energy Meter 8
2
Shelly Pro EM-50
2
Aeotec Home Energy Meter 8
Yes
Catalog note

Reports V, A, W, kWh, power factor and reactive power

Shelly Pro EM-50
Yes
Catalog note

Active and apparent power, power factor, frequency and voltage

Aeotec Home Energy Meter 8
Yes
Shelly Pro EM-50
No
Catalog note

Single-phase device with two current channels

Aeotec Home Energy Meter 8
No
Catalog note

The US model is the 2-phase / split-phase variant; three-phase is a separate EU version

Shelly Pro EM-50
No
Specifications for Aeotec Home Energy Meter 8 versus Shelly Pro EM-50
SpecificationAeotec Home Energy Meter 8Shelly Pro EM-50
Connectivity
NoYes
NoNo
NoYes
Catalog note

Bluetooth 4.2, also works as a Bluetooth gateway

NoYes
NoModbus
NoNo
Z-Wave Hub required
Catalog note

Z-Wave 800 series with Long Range, S2 security, also acts as a repeater

No
NoNo
Data Monitoring
Not applicable / unspecifiedYes
Catalog note

CSV export of the consumption chart

Not applicable / unspecified60 days
Catalog note

At least 60 days of 1-minute data stored on the device

Not applicable / unspecifiedYes
Not recordedNot recorded
Not applicable / unspecifiedYes
Catalog note

Cost periods and tariff distribution in the Shelly Smart Control app

Not applicable / unspecifiedYes
Features
Yes
Catalog note

Through the Z-Wave hub, not the device itself

Yes
NoYes
Catalog note

Configurable load control to divert surplus PV production

NoYes
Catalog note

Integrated switch with potential-free contacts, 2 A at 240 V

Installation
YesYes
NoYes
Catalog note

One DIN module wide

Mains (120 V)Mains (100-260 V)
NoNo
Integrations
No
Catalog note

Alexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish

Yes
NoNo
Not recordedYes
Yes
Catalog note

Via the Z-Wave JS integration

Yes
NoNo
YesYes
Catalog note

Via the official Shelly Cloud integration

Local Control
NoYes
Catalog note

RPC over HTTPS and WebSocket, UDP, webhooks, scripting and Modbus TCP

NoYes
NoYes
Metering
99%
Catalog note

Better than 99% above 0.05 A

±1%
Catalog note

Accuracy Class B for active energy, ±1% from 5 A to 50 A

YesYes
Catalog note

4 quadrant measurement with a returned energy counter

Not applicable / unspecifiedNot applicable / unspecified
2
Catalog note

2 x 200 A clamps for the service mains

2
Catalog note

2 x 50 A current transformers

200 A50 A
22
Yes
Catalog note

Reports V, A, W, kWh, power factor and reactive power

Yes
Catalog note

Active and apparent power, power factor, frequency and voltage

YesNo
Catalog note

Single-phase device with two current channels

No
Catalog note

The US model is the 2-phase / split-phase variant; three-phase is a separate EU version