The Smart Device Compare comparison

Aeotec Home Energy Meter 8 vs Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)

Understand the differences. Decide what matters to your home.

Build another comparison →

Before you compare every specification

Key differences between Aeotec Home Energy Meter 8 and Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)

A summary of selected recorded differences between these energy monitors. Check the full specification table below for details and conditions.

Feature differences among your selected devices
  • 2.4 GHz Wi-Fi (connectivity): Aeotec Home Energy Meter 8 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Yes (IEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6).
  • Alexa (integrations): Aeotec Home Energy Meter 8 — No (Alexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Yes (Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model).
  • Matter (integrations): Aeotec Home Energy Meter 8 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Yes (Matter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems).
  • Local Api (local control): Aeotec Home Energy Meter 8 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Yes (JSON-RPC 2.0 over HTTP and WebSocket, documented as an open API).
Specifications to check side by side
  • Z Wave (connectivity): Aeotec Home Energy Meter 8 — Z-Wave Hub required (Z-Wave 800 series with Long Range, S2 security, also acts as a repeater); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — No.
  • Power Supply (installation): Aeotec Home Energy Meter 8 — Mains (120 V); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Mains (100-240 V).
  • Apple Home (integrations): Aeotec Home Energy Meter 8 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Upcoming platform support (The meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type.).
  • Monitored Circuits (metering): Aeotec Home Energy Meter 8 — 2; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — 1 (One circuit, the load wired through its L and L Out terminals).
Information still to confirm
  • 12 of 39 comparison fields lack a resolved value for at least one selected device. Missing information is not evidence that a feature is absent.
  • Check the full table and manufacturer documentation before ruling out a device.

These observations are derived from recorded catalog data and have not all been independently verified. Confirm details with the manufacturer before purchasing.

Compare capabilities, compatibility and setup requirements.

What the catalog tells us

Understand the tradeoffs.

These counts describe the available data, not a quality score. More features do not automatically make a better device.

12differences with recorded values for every device
12rows with missing or unspecified information

Consider your setup

Apple Home

  • Aeotec Home Energy Meter 8No
  • Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)Upcoming platform support

Confirm which features appear in Apple Home and whether extra hardware or a subscription is needed for your intended use.

Inspect the specifications

Consider your setup

Matter

  • Aeotec Home Energy Meter 8No
  • Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)Yes

Confirm the exact device type and the features exposed in your chosen platform. Protocol support does not establish feature parity across apps.

Inspect the specifications

Your priorities, side by side

Focus on what changes.

Mark the specifications you care about. Open manufacturer sources for verification scope; fields without citations remain catalog data. Expand notes for other qualifications.

Showing 39 of 39 rows. “Not recorded” does not mean “No”.

Connectivity

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

IEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Not recorded
Catalog note

The spec sheet lists Wi-Fi only, while the FCC grant authorises a second 2402-2480 MHz transmitter, so the radio is there but SONOFF never documents it as a feature

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Aeotec Home Energy Meter 8
Z-Wave Hub required
Catalog note

Z-Wave 800 series with Long Range, S2 security, also acts as a repeater

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Catalog note

The Zigbee version of this meter is a separate model, the MINI-ZB1GP

Data Monitoring

Aeotec Home Energy Meter 8
Not applicable / unspecified
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Energy data and electricity bills export to a spreadsheet, from the app and from the local console

Aeotec Home Energy Meter 8
Not applicable / unspecified
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
1 year
Catalog note

Up to one year of energy data, and going offline does not interrupt the recording

Aeotec Home Energy Meter 8
Not applicable / unspecified
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Custom currency and electricity rate, with the bill broken down in charts

Aeotec Home Energy Meter 8
Not recorded
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Not recorded
Aeotec Home Energy Meter 8
Not applicable / unspecified
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Fixed or time-of-use pricing, with consumption shown per rate band

Aeotec Home Energy Meter 8
Not applicable / unspecified
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Overcurrent, overpower, overvoltage and undervoltage thresholds, plus a run completion alert and a maintenance reminder based on accumulated runtime

Features

Aeotec Home Energy Meter 8
Yes
Catalog note

Through the Z-Wave hub, not the device itself

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Quick Scenes in eWeLink, and its readings drive automations in Home Assistant

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Catalog note

With no relay it can raise a threshold alert but cannot shed the load itself

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Catalog note

SONOFF states this is a non-switch product that cannot control the load it measures

Installation

Aeotec Home Energy Meter 8
Yes
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Wires into live and neutral behind a socket or inside a junction box, and SONOFF recommends a wall box at least 60 mm deep

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Catalog note

Indoor flush mounting only, with no rail clip

Aeotec Home Energy Meter 8
Mains (120 V)
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Mains (100-240 V)
Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No

Integrations

Aeotec Home Energy Meter 8
No
Catalog note

Alexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Upcoming platform support
Catalog note

The meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type.

Aeotec Home Energy Meter 8
Not recorded
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model

Aeotec Home Energy Meter 8
Yes
Catalog note

Via the Z-Wave JS integration

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

SONOFF's platform table gives Home Assistant two routes, Matter and MQTT discovery, and both carry the voltage, current, power and energy readings

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Matter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems

Aeotec Home Energy Meter 8
Yes
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

Reached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures

Local Control

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Catalog note

JSON-RPC 2.0 over HTTP and WebSocket, documented as an open API

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Manufacturer source

A local browser console is provided.

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
Source section
Product description / feature descriptions
Model
MINI-1GP
Region
Manufacturer listing for the named model/variant; regional equivalence has not been established
Firmware
Not specified by this source
Checked

This product measures energy and does not switch the attached load.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

The OpenEdge web console runs on the device and needs no app and no account

Aeotec Home Energy Meter 8
No
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Manufacturer source

MQTT access is listed.

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
Source section
Product description / feature descriptions
Model
MINI-1GP
Region
Manufacturer listing for the named model/variant; regional equivalence has not been established
Firmware
Not specified by this source
Checked

This product measures energy and does not switch the attached load.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

MQTT is configured from the device itself and is how Home Assistant reads the meter with no cloud in the path

Metering

Aeotec Home Energy Meter 8
99%
Catalog note

Better than 99% above 0.05 A

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Not recorded
Aeotec Home Energy Meter 8
Yes
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Yes
Manufacturer source

Bidirectional energy metering is supported.

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
Source section
Product description / feature descriptions
Model
MINI-1GP
Region
Manufacturer listing for the named model/variant; regional equivalence has not been established
Firmware
Not specified by this source
Checked

This product measures energy and does not switch the attached load.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

Bi-directional metering separates what the load consumes from what a balcony solar array produces, which the app can record as a negative value

Aeotec Home Energy Meter 8
Not applicable / unspecified
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Not applicable / unspecified
Aeotec Home Energy Meter 8
2
Catalog note

2 x 200 A clamps for the service mains

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Not applicable / unspecified
Catalog note

Inline measurement, no current transformer involved

Aeotec Home Energy Meter 8
200 A
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Not applicable / unspecified
Aeotec Home Energy Meter 8
2
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
1
Catalog note

One circuit, the load wired through its L and L Out terminals

Aeotec Home Energy Meter 8
Yes
Catalog note

Reports V, A, W, kWh, power factor and reactive power

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Catalog note

SONOFF documents real-time voltage, current, power and accumulated energy, with no power factor reading

Aeotec Home Energy Meter 8
Yes
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Catalog note

Rated 100-240V~ 50/60Hz on a single line, so a 120/240 V split-phase service is out of scope

Aeotec Home Energy Meter 8
No
Catalog note

The US model is the 2-phase / split-phase variant; three-phase is a separate EU version

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
No
Specifications for Aeotec Home Energy Meter 8 versus Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
SpecificationAeotec Home Energy Meter 8Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Connectivity
NoYes
Catalog note

IEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6

NoNo
NoNot recorded
Catalog note

The spec sheet lists Wi-Fi only, while the FCC grant authorises a second 2402-2480 MHz transmitter, so the radio is there but SONOFF never documents it as a feature

NoNo
NoNo
NoNo
Z-Wave Hub required
Catalog note

Z-Wave 800 series with Long Range, S2 security, also acts as a repeater

No
NoNo
Catalog note

The Zigbee version of this meter is a separate model, the MINI-ZB1GP

Data Monitoring
Not applicable / unspecifiedYes
Catalog note

Energy data and electricity bills export to a spreadsheet, from the app and from the local console

Not applicable / unspecified1 year
Catalog note

Up to one year of energy data, and going offline does not interrupt the recording

Not applicable / unspecifiedYes
Catalog note

Custom currency and electricity rate, with the bill broken down in charts

Not recordedNot recorded
Not applicable / unspecifiedYes
Catalog note

Fixed or time-of-use pricing, with consumption shown per rate band

Not applicable / unspecifiedYes
Catalog note

Overcurrent, overpower, overvoltage and undervoltage thresholds, plus a run completion alert and a maintenance reminder based on accumulated runtime

Features
Yes
Catalog note

Through the Z-Wave hub, not the device itself

Yes
Catalog note

Quick Scenes in eWeLink, and its readings drive automations in Home Assistant

NoNo
Catalog note

With no relay it can raise a threshold alert but cannot shed the load itself

NoNo
Catalog note

SONOFF states this is a non-switch product that cannot control the load it measures

Installation
YesYes
Catalog note

Wires into live and neutral behind a socket or inside a junction box, and SONOFF recommends a wall box at least 60 mm deep

NoNo
Catalog note

Indoor flush mounting only, with no rail clip

Mains (120 V)Mains (100-240 V)
NoNo
Integrations
No
Catalog note

Alexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish

Yes
Catalog note

Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model

NoUpcoming platform support
Catalog note

The meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type.

Not recordedYes
Catalog note

Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model

Yes
Catalog note

Via the Z-Wave JS integration

Yes
Catalog note

SONOFF's platform table gives Home Assistant two routes, Matter and MQTT discovery, and both carry the voltage, current, power and energy readings

NoYes
Catalog note

Matter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems

YesYes
Catalog note

Reached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures

Local Control
NoYes
Catalog note

JSON-RPC 2.0 over HTTP and WebSocket, documented as an open API

NoYes
Manufacturer source

A local browser console is provided.

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
Source section
Product description / feature descriptions
Model
MINI-1GP
Region
Manufacturer listing for the named model/variant; regional equivalence has not been established
Firmware
Not specified by this source
Checked

This product measures energy and does not switch the attached load.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

The OpenEdge web console runs on the device and needs no app and no account

NoYes
Manufacturer source

MQTT access is listed.

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
Source section
Product description / feature descriptions
Model
MINI-1GP
Region
Manufacturer listing for the named model/variant; regional equivalence has not been established
Firmware
Not specified by this source
Checked

This product measures energy and does not switch the attached load.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

MQTT is configured from the device itself and is how Home Assistant reads the meter with no cloud in the path

Metering
99%
Catalog note

Better than 99% above 0.05 A

Not recorded
YesYes
Manufacturer source

Bidirectional energy metering is supported.

Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
Source section
Product description / feature descriptions
Model
MINI-1GP
Region
Manufacturer listing for the named model/variant; regional equivalence has not been established
Firmware
Not specified by this source
Checked

This product measures energy and does not switch the attached load.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

Bi-directional metering separates what the load consumes from what a balcony solar array produces, which the app can record as a negative value

Not applicable / unspecifiedNot applicable / unspecified
2
Catalog note

2 x 200 A clamps for the service mains

Not applicable / unspecified
Catalog note

Inline measurement, no current transformer involved

200 ANot applicable / unspecified
21
Catalog note

One circuit, the load wired through its L and L Out terminals

Yes
Catalog note

Reports V, A, W, kWh, power factor and reactive power

No
Catalog note

SONOFF documents real-time voltage, current, power and accumulated energy, with no power factor reading

YesNo
Catalog note

Rated 100-240V~ 50/60Hz on a single line, so a 120/240 V split-phase service is out of scope

No
Catalog note

The US model is the 2-phase / split-phase variant; three-phase is a separate EU version

No

Know what’s behind the comparison.

The table matches specifications by section and field. It preserves notes, separates missing data from explicit “No” values, and keeps qualifications attached to their values. No overall winner is assigned from feature counts.

Read our comparison methodology