The Smart Device Compare comparison
Emporia Vue 3 vs Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Understand the differences. Decide what matters to your home.
Build another comparison →Before you compare every specification
Key differences between Emporia Vue 3 and Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
A summary of selected recorded differences between these energy monitors. Check the full specification table below for details and conditions.
- Ethernet (connectivity): Emporia Vue 3 — Yes (10/100Base-T); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — No.
- Load Management (features): Emporia Vue 3 — Yes (Time of use, peak demand and excess solar automations); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — No (With no relay it can raise a threshold alert but cannot shed the load itself).
- Matter (integrations): Emporia Vue 3 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Yes (Matter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems).
- SmartThings (integrations): Emporia Vue 3 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Yes (Reached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures).
- Data History (data monitoring): Emporia Vue 3 — Unlimited (1 second data 3 hours, 1 minute data 7 days, 1 hour data unlimited); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — 1 year (Up to one year of energy data, and going offline does not interrupt the recording).
- Power Supply (installation): Emporia Vue 3 — Mains (breaker panel); Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Mains (100-240 V).
- Apple Home (integrations): Emporia Vue 3 — No; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — Upcoming platform support (The meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type.).
- Monitored Circuits (metering): Emporia Vue 3 — 19; Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — 1 (One circuit, the load wired through its L and L Out terminals).
- 6 of 39 comparison fields lack a resolved value for at least one selected device. Missing information is not evidence that a feature is absent.
- Check the full table and manufacturer documentation before ruling out a device.
These observations are derived from recorded catalog data and have not all been independently verified. Confirm details with the manufacturer before purchasing.
Compare capabilities, compatibility and setup requirements.


Option 2 · Sonoff
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Last updated October 2026
View full device profileWhat the catalog tells us
Understand the tradeoffs.
These counts describe the available data, not a quality score. More features do not automatically make a better device.
Consider your setup
Apple Home
- Emporia Vue 3No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)Upcoming platform support
Confirm which features appear in Apple Home and whether extra hardware or a subscription is needed for your intended use.
Inspect the specificationsConsider your setup
Matter
- Emporia Vue 3No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)Yes
Confirm the exact device type and the features exposed in your chosen platform. Protocol support does not establish feature parity across apps.
Inspect the specificationsYour priorities, side by side
Focus on what changes.
Mark the specifications you care about. Open manufacturer sources for verification scope; fields without citations remain catalog data. Expand notes for other qualifications.
Showing 39 of 39 rows. “Not recorded” does not mean “No”.
Connectivity
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
IEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Not recorded
Catalog note
The spec sheet lists Wi-Fi only, while the FCC grant authorises a second 2402-2480 MHz transmitter, so the radio is there but SONOFF never documents it as a feature
- Emporia Vue 3
- Yes
Catalog note
10/100Base-T
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Catalog note
The Zigbee version of this meter is a separate model, the MINI-ZB1GP
Data Monitoring
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Energy data and electricity bills export to a spreadsheet, from the app and from the local console
- Emporia Vue 3
- Unlimited
Catalog note
1 second data 3 hours, 1 minute data 7 days, 1 hour data unlimited
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- 1 year
Catalog note
Up to one year of energy data, and going offline does not interrupt the recording
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Custom currency and electricity rate, with the bill broken down in charts
- Emporia Vue 3
- 1 s
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Not recorded
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Fixed or time-of-use pricing, with consumption shown per rate band
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Overcurrent, overpower, overvoltage and undervoltage thresholds, plus a run completion alert and a maintenance reminder based on accumulated runtime
Features
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Quick Scenes in eWeLink, and its readings drive automations in Home Assistant
- Emporia Vue 3
- Yes
Catalog note
Time of use, peak demand and excess solar automations
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Catalog note
With no relay it can raise a threshold alert but cannot shed the load itself
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Catalog note
SONOFF states this is a non-switch product that cannot control the load it measures
Installation
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Wires into live and neutral behind a socket or inside a junction box, and SONOFF recommends a wall box at least 60 mm deep
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Catalog note
Indoor flush mounting only, with no rail clip
- Emporia Vue 3
- Mains (breaker panel)
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Mains (100-240 V)
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Integrations
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Upcoming platform support
Catalog note
The meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type.
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model
- Emporia Vue 3
- Yes
Catalog note
Community Emporia Vue integration for Home Assistant (HACS), which covers the Vue monitors and the Utility Connect
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
SONOFF's platform table gives Home Assistant two routes, Matter and MQTT discovery, and both carry the voltage, current, power and energy readings
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Matter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
Reached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures
Local Control
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Catalog note
JSON-RPC 2.0 over HTTP and WebSocket, documented as an open API
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Manufacturer source
A local browser console is provided.
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →- Source section
- Product description / feature descriptions
- Model
- MINI-1GP
- Region
- Manufacturer listing for the named model/variant; regional equivalence has not been established
- Firmware
- Not specified by this source
- Checked
This product measures energy and does not switch the attached load.
Document check only; not a hands-on test or verification of every regional or firmware variant.
Catalog note
The OpenEdge web console runs on the device and needs no app and no account
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Manufacturer source
MQTT access is listed.
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →- Source section
- Product description / feature descriptions
- Model
- MINI-1GP
- Region
- Manufacturer listing for the named model/variant; regional equivalence has not been established
- Firmware
- Not specified by this source
- Checked
This product measures energy and does not switch the attached load.
Document check only; not a hands-on test or verification of every regional or firmware variant.
Catalog note
MQTT is configured from the device itself and is how Home Assistant reads the meter with no cloud in the path
Metering
- Emporia Vue 3
- ±2%
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Not recorded
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Yes
Manufacturer source
Bidirectional energy metering is supported.
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →- Source section
- Product description / feature descriptions
- Model
- MINI-1GP
- Region
- Manufacturer listing for the named model/variant; regional equivalence has not been established
- Firmware
- Not specified by this source
- Checked
This product measures energy and does not switch the attached load.
Document check only; not a hands-on test or verification of every regional or firmware variant.
Catalog note
Bi-directional metering separates what the load consumes from what a balcony solar array produces, which the app can record as a negative value
- Emporia Vue 3
- 50 A
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Not applicable / unspecified
- Emporia Vue 3
- 18
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Not applicable / unspecified
Catalog note
Inline measurement, no current transformer involved
- Emporia Vue 3
- 200 A
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- Not applicable / unspecified
- Emporia Vue 3
- 19
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- 1
Catalog note
One circuit, the load wired through its L and L Out terminals
- Emporia Vue 3
- No
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Catalog note
SONOFF documents real-time voltage, current, power and accumulated energy, with no power factor reading
- Emporia Vue 3
- Yes
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
Catalog note
Rated 100-240V~ 50/60Hz on a single line, so a 120/240 V split-phase service is out of scope
- Emporia Vue 3
- Sold separately
Catalog note
3-phase 4-wire Wye needs an extra 200 A sensor
- Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
- No
| Specification | Emporia Vue 3 | Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) |
|---|---|---|
| Connectivity | ||
| Yes | YesCatalog noteIEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6 | |
| No | No | |
| No | Not recordedCatalog noteThe spec sheet lists Wi-Fi only, while the FCC grant authorises a second 2402-2480 MHz transmitter, so the radio is there but SONOFF never documents it as a feature | |
YesCatalog note10/100Base-T | No | |
| No | No | |
| No | No | |
| No | No | |
| No | NoCatalog noteThe Zigbee version of this meter is a separate model, the MINI-ZB1GP | |
| Data Monitoring | ||
| Yes | YesCatalog noteEnergy data and electricity bills export to a spreadsheet, from the app and from the local console | |
UnlimitedCatalog note1 second data 3 hours, 1 minute data 7 days, 1 hour data unlimited | 1 yearCatalog noteUp to one year of energy data, and going offline does not interrupt the recording | |
| Yes | YesCatalog noteCustom currency and electricity rate, with the bill broken down in charts | |
| 1 s | Not recorded | |
| Yes | YesCatalog noteFixed or time-of-use pricing, with consumption shown per rate band | |
| Yes | YesCatalog noteOvercurrent, overpower, overvoltage and undervoltage thresholds, plus a run completion alert and a maintenance reminder based on accumulated runtime | |
| Features | ||
| Yes | YesCatalog noteQuick Scenes in eWeLink, and its readings drive automations in Home Assistant | |
YesCatalog noteTime of use, peak demand and excess solar automations | NoCatalog noteWith no relay it can raise a threshold alert but cannot shed the load itself | |
| No | NoCatalog noteSONOFF states this is a non-switch product that cannot control the load it measures | |
| Installation | ||
| Yes | YesCatalog noteWires into live and neutral behind a socket or inside a junction box, and SONOFF recommends a wall box at least 60 mm deep | |
| No | NoCatalog noteIndoor flush mounting only, with no rail clip | |
| Mains (breaker panel) | Mains (100-240 V) | |
| No | No | |
| Integrations | ||
| Yes | YesCatalog noteReached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model | |
| No | Upcoming platform supportCatalog noteThe meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type. | |
| Yes | YesCatalog noteReached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model | |
YesCatalog noteCommunity Emporia Vue integration for Home Assistant (HACS), which covers the Vue monitors and the Utility Connect | YesCatalog noteSONOFF's platform table gives Home Assistant two routes, Matter and MQTT discovery, and both carry the voltage, current, power and energy readings | |
| No | YesCatalog noteMatter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems | |
| No | YesCatalog noteReached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures | |
| Local Control | ||
| No | YesCatalog noteJSON-RPC 2.0 over HTTP and WebSocket, documented as an open API | |
| No | YesManufacturer sourceA local browser console is provided. Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
This product measures energy and does not switch the attached load. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteThe OpenEdge web console runs on the device and needs no app and no account | |
| No | YesManufacturer sourceMQTT access is listed. Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
This product measures energy and does not switch the attached load. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteMQTT is configured from the device itself and is how Home Assistant reads the meter with no cloud in the path | |
| Metering | ||
| ±2% | Not recorded | |
| Yes | YesManufacturer sourceBidirectional energy metering is supported. Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
This product measures energy and does not switch the attached load. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteBi-directional metering separates what the load consumes from what a balcony solar array produces, which the app can record as a negative value | |
| 50 A | Not applicable / unspecified | |
| 18 | Not applicable / unspecifiedCatalog noteInline measurement, no current transformer involved | |
| 200 A | Not applicable / unspecified | |
| 19 | 1Catalog noteOne circuit, the load wired through its L and L Out terminals | |
| No | NoCatalog noteSONOFF documents real-time voltage, current, power and accumulated energy, with no power factor reading | |
| Yes | NoCatalog noteRated 100-240V~ 50/60Hz on a single line, so a 120/240 V split-phase service is out of scope | |
Sold separatelyCatalog note3-phase 4-wire Wye needs an extra 200 A sensor | No | |
Know what’s behind the comparison.
The table matches specifications by section and field. It preserves notes, separates missing data from explicit “No” values, and keeps qualifications attached to their values. No overall winner is assigned from feature counts.
Read our comparison methodology