The Smart Device Compare comparison
Shelly EM Mini Gen4 vs Shelly Pro EM-50
Understand the differences. Decide what matters to your home.
Build another comparison →Before you compare every specification
Key differences between Shelly EM Mini Gen4 and Shelly Pro EM-50
A summary of selected recorded differences between these energy monitors. Check the full specification table below for details and conditions.
- Ethernet (connectivity): Shelly EM Mini Gen4 — No; Shelly Pro EM-50 — Yes.
- Load Management (features): Shelly EM Mini Gen4 — No; Shelly Pro EM-50 — Yes (Configurable load control to divert surplus PV production).
- Relay Output (features): Shelly EM Mini Gen4 — No (Pure meter, it cannot switch the load it measures); Shelly Pro EM-50 — Yes (Integrated switch with potential-free contacts, 2 A at 240 V).
- Din Rail Mount (installation): Shelly EM Mini Gen4 — No; Shelly Pro EM-50 — Yes (One DIN module wide).
- Other (connectivity): Shelly EM Mini Gen4 — No; Shelly Pro EM-50 — Modbus.
- Zigbee (connectivity): Shelly EM Mini Gen4 — Zigbee Hub required (Zigbee 802.15.4, also acts as a repeater); Shelly Pro EM-50 — No.
- Data History (data monitoring): Shelly EM Mini Gen4 — 10 days (At least 10 days of 1-minute records on the device); Shelly Pro EM-50 — 60 days (At least 60 days of 1-minute data stored on the device).
- Power Supply (installation): Shelly EM Mini Gen4 — Mains (110-240 V); Shelly Pro EM-50 — Mains (100-260 V).
- 6 of 39 comparison fields lack a resolved value for at least one selected device. Missing information is not evidence that a feature is absent.
- Check the full table and manufacturer documentation before ruling out a device.
These observations are derived from recorded catalog data and have not all been independently verified. Confirm details with the manufacturer before purchasing.
Compare capabilities, compatibility and setup requirements.


What the catalog tells us
Understand the tradeoffs.
These counts describe the available data, not a quality score. More features do not automatically make a better device.
Consider your setup
Apple Home
- Shelly EM Mini Gen4Yes
- Shelly Pro EM-50No
Confirm which features appear in Apple Home and whether extra hardware or a subscription is needed for your intended use.
Inspect the specificationsConsider your setup
Matter
- Shelly EM Mini Gen4Yes
- Shelly Pro EM-50No
Confirm the exact device type and the features exposed in your chosen platform. Protocol support does not establish feature parity across apps.
Inspect the specificationsYour priorities, side by side
Focus on what changes.
Mark the specifications you care about. Open manufacturer sources for verification scope; fields without citations remain catalog data. Expand notes for other qualifications.
Showing 39 of 39 rows. “Not recorded” does not mean “No”.
Connectivity
- Shelly EM Mini Gen4
- Yes
Catalog note
Wi-Fi 6 (802.11 b/g/n/ax) on 2.4 GHz
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- No
- Shelly EM Mini Gen4
- Yes
Catalog note
Bluetooth 5.0
- Shelly Pro EM-50
- Yes
Catalog note
Bluetooth 4.2, also works as a Bluetooth gateway
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- Modbus
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- No
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- No
- Shelly EM Mini Gen4
- Zigbee Hub required
Catalog note
Zigbee 802.15.4, also acts as a repeater
- Shelly Pro EM-50
- No
Data Monitoring
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
Catalog note
CSV export of the consumption chart
- Shelly EM Mini Gen4
- 10 days
Catalog note
At least 10 days of 1-minute records on the device
- Shelly Pro EM-50
- 60 days
Catalog note
At least 60 days of 1-minute data stored on the device
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- Not recorded
- Shelly Pro EM-50
- Not recorded
- Shelly EM Mini Gen4
- Yes
Catalog note
Cost periods and tariff distribution in the Shelly Smart Control app
- Shelly Pro EM-50
- Yes
Catalog note
Cost periods and tariff distribution in the Shelly Smart Control app
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
Features
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- Yes
Catalog note
Configurable load control to divert surplus PV production
- Shelly EM Mini Gen4
- No
Catalog note
Pure meter, it cannot switch the load it measures
- Shelly Pro EM-50
- Yes
Catalog note
Integrated switch with potential-free contacts, 2 A at 240 V
Installation
- Shelly EM Mini Gen4
- Yes
Catalog note
Small enough for a wall box, a socket back box or the inside of an appliance
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- Yes
Catalog note
One DIN module wide
- Shelly EM Mini Gen4
- Mains (110-240 V)
- Shelly Pro EM-50
- Mains (100-260 V)
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- No
Integrations
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- Yes
Catalog note
Via Matter
- Shelly Pro EM-50
- No
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- No
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
Catalog note
Via the official Shelly Cloud integration
Local Control
- Shelly EM Mini Gen4
- Yes
Catalog note
RPC over HTTP and WebSocket, plus webhooks and scripting
- Shelly Pro EM-50
- Yes
Catalog note
RPC over HTTPS and WebSocket, UDP, webhooks, scripting and Modbus TCP
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
- Shelly EM Mini Gen4
- Yes
- Shelly Pro EM-50
- Yes
Metering
- Shelly EM Mini Gen4
- ±1%
Catalog note
±1% on both the voltmeter and the ammeter
- Shelly Pro EM-50
- ±1%
Catalog note
Accuracy Class B for active energy, ±1% from 5 A to 50 A
- Shelly EM Mini Gen4
- Not recorded
- Shelly Pro EM-50
- Yes
Catalog note
4 quadrant measurement with a returned energy counter
- Shelly EM Mini Gen4
- Not applicable / unspecified
- Shelly Pro EM-50
- Not applicable / unspecified
- Shelly EM Mini Gen4
- Not applicable / unspecified
Catalog note
Inline measurement, no current transformer needed
- Shelly Pro EM-50
- 2
Catalog note
2 x 50 A current transformers
- Shelly EM Mini Gen4
- Not applicable / unspecified
- Shelly Pro EM-50
- 50 A
- Shelly EM Mini Gen4
- 1
- Shelly Pro EM-50
- 2
- Shelly EM Mini Gen4
- Not recorded
- Shelly Pro EM-50
- Yes
Catalog note
Active and apparent power, power factor, frequency and voltage
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- No
Catalog note
Single-phase device with two current channels
- Shelly EM Mini Gen4
- No
- Shelly Pro EM-50
- No
| Specification | Shelly EM Mini Gen4 | Shelly Pro EM-50 |
|---|---|---|
| Connectivity | ||
YesCatalog noteWi-Fi 6 (802.11 b/g/n/ax) on 2.4 GHz | Yes | |
| No | No | |
YesCatalog noteBluetooth 5.0 | YesCatalog noteBluetooth 4.2, also works as a Bluetooth gateway | |
| No | Yes | |
| No | Modbus | |
| No | No | |
| No | No | |
Zigbee Hub requiredCatalog noteZigbee 802.15.4, also acts as a repeater | No | |
| Data Monitoring | ||
| Yes | YesCatalog noteCSV export of the consumption chart | |
10 daysCatalog noteAt least 10 days of 1-minute records on the device | 60 daysCatalog noteAt least 60 days of 1-minute data stored on the device | |
| Yes | Yes | |
| Not recorded | Not recorded | |
YesCatalog noteCost periods and tariff distribution in the Shelly Smart Control app | YesCatalog noteCost periods and tariff distribution in the Shelly Smart Control app | |
| Yes | Yes | |
| Features | ||
| Yes | Yes | |
| No | YesCatalog noteConfigurable load control to divert surplus PV production | |
NoCatalog notePure meter, it cannot switch the load it measures | YesCatalog noteIntegrated switch with potential-free contacts, 2 A at 240 V | |
| Installation | ||
YesCatalog noteSmall enough for a wall box, a socket back box or the inside of an appliance | Yes | |
| No | YesCatalog noteOne DIN module wide | |
| Mains (110-240 V) | Mains (100-260 V) | |
| No | No | |
| Integrations | ||
| Yes | Yes | |
YesCatalog noteVia Matter | No | |
| Yes | Yes | |
| Yes | Yes | |
| Yes | No | |
| Yes | YesCatalog noteVia the official Shelly Cloud integration | |
| Local Control | ||
YesCatalog noteRPC over HTTP and WebSocket, plus webhooks and scripting | YesCatalog noteRPC over HTTPS and WebSocket, UDP, webhooks, scripting and Modbus TCP | |
| Yes | Yes | |
| Yes | Yes | |
| Metering | ||
±1%Catalog note±1% on both the voltmeter and the ammeter | ±1%Catalog noteAccuracy Class B for active energy, ±1% from 5 A to 50 A | |
| Not recorded | YesCatalog note4 quadrant measurement with a returned energy counter | |
| Not applicable / unspecified | Not applicable / unspecified | |
Not applicable / unspecifiedCatalog noteInline measurement, no current transformer needed | 2Catalog note2 x 50 A current transformers | |
| Not applicable / unspecified | 50 A | |
| 1 | 2 | |
| Not recorded | YesCatalog noteActive and apparent power, power factor, frequency and voltage | |
| No | NoCatalog noteSingle-phase device with two current channels | |
| No | No | |
Know what’s behind the comparison.
The table matches specifications by section and field. It preserves notes, separates missing data from explicit “No” values, and keeps qualifications attached to their values. No overall winner is assigned from feature counts.
Read our comparison methodology