Option 1 · Sonoff
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch)
Last updated October 2026
View full device profileThe Smart Device Compare comparison
Understand the differences. Decide what matters to your home.
Build another comparison →Before you compare every specification
A summary of selected recorded differences between these energy monitors. Check the full specification table below for details and conditions.
These observations are derived from recorded catalog data and have not all been independently verified. Confirm details with the manufacturer before purchasing.
Compare capabilities, compatibility and setup requirements.

Option 1 · Sonoff
Last updated October 2026
View full device profile
What the catalog tells us
These counts describe the available data, not a quality score. More features do not automatically make a better device.
Consider your setup
Confirm which features appear in Apple Home and whether extra hardware or a subscription is needed for your intended use.
Inspect the specificationsConsider your setup
Confirm the exact device type and the features exposed in your chosen platform. Protocol support does not establish feature parity across apps.
Inspect the specificationsYour priorities, side by side
Mark the specifications you care about. Open manufacturer sources for verification scope; fields without citations remain catalog data. Expand notes for other qualifications.
Showing 39 of 39 rows. “Not recorded” does not mean “No”.
IEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6
The spec sheet lists Wi-Fi only, while the FCC grant authorises a second 2402-2480 MHz transmitter, so the radio is there but SONOFF never documents it as a feature
The Zigbee version of this meter is a separate model, the MINI-ZB1GP
Zigbee 3.0 on a Tuya ZS2S module, works with any certified hub, no Tuya gateway needed
Energy data and electricity bills export to a spreadsheet, from the app and from the local console
Up to one year of energy data, and going offline does not interrupt the recording
Accumulated, hourly, daily and monthly totals, history lives in the hub
Custom currency and electricity rate, with the bill broken down in charts
Reporting interval adjustable per value, 30 seconds by default
Fixed or time-of-use pricing, with consumption shown per rate band
Overcurrent, overpower, overvoltage and undervoltage thresholds, plus a run completion alert and a maintenance reminder based on accumulated runtime
Quick Scenes in eWeLink, and its readings drive automations in Home Assistant
Through the Zigbee hub or Home Assistant, not the device itself
With no relay it can raise a threshold alert but cannot shed the load itself
SONOFF states this is a non-switch product that cannot control the load it measures
Wires into live and neutral behind a socket or inside a junction box, and SONOFF recommends a wall box at least 60 mm deep
Indoor flush mounting only, with no rail clip
18 mm wide body that sits above or below the circuit breakers without taking a DIN module
Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model
Alexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish
The meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type.
Reached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model
SONOFF's platform table gives Home Assistant two routes, Matter and MQTT discovery, and both carry the voltage, current, power and energy readings
Home Assistant use through Zigbee2MQTT is documented.
Zemismart SPM01 manufacturer product page →A compatible Zigbee coordinator and integration are required.
Document check only; not a hands-on test or verification of every regional or firmware variant.
Via Zigbee2MQTT or ZHA
Matter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems
Reached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures
Pairs with a SmartThings hub as a standard Zigbee 3.0 device
JSON-RPC 2.0 over HTTP and WebSocket, documented as an open API
A local browser console is provided.
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →This product measures energy and does not switch the attached load.
Document check only; not a hands-on test or verification of every regional or firmware variant.
The OpenEdge web console runs on the device and needs no app and no account
MQTT access is listed.
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →This product measures energy and does not switch the attached load.
Document check only; not a hands-on test or verification of every regional or firmware variant.
MQTT is configured from the device itself and is how Home Assistant reads the meter with no cloud in the path
No native MQTT, though Zigbee2MQTT republishes the readings
Accuracy Class 1 per IEC 61557-12
Bidirectional energy metering is supported.
Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →This product measures energy and does not switch the attached load.
Document check only; not a hands-on test or verification of every regional or firmware variant.
Bi-directional metering separates what the load consumes from what a balcony solar array produces, which the app can record as a negative value
Separate forward and reverse energy totals for solar
Inline measurement, no current transformer involved
Inline measurement, the conductor is threaded through the body
Rated up to 63 A without a current transformer
One circuit, the load wired through its L and L Out terminals
The meter monitors a single-phase circuit.
Zemismart SPM01 manufacturer product page →A compatible Zigbee coordinator and integration are required.
Document check only; not a hands-on test or verification of every regional or firmware variant.
SONOFF documents real-time voltage, current, power and accumulated energy, with no power factor reading
Voltage, current, power, power factor and energy
Rated 100-240V~ 50/60Hz on a single line, so a 120/240 V split-phase service is out of scope
| Specification | Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) | Zemismart SPM01 |
|---|---|---|
| Connectivity | ||
YesCatalog noteIEEE 802.11 b/g/n on 2.4 GHz, from an ESP32-C6 | No | |
| No | No | |
Not recordedCatalog noteThe spec sheet lists Wi-Fi only, while the FCC grant authorises a second 2402-2480 MHz transmitter, so the radio is there but SONOFF never documents it as a feature | No | |
| No | No | |
| No | No | |
| No | No | |
| No | No | |
NoCatalog noteThe Zigbee version of this meter is a separate model, the MINI-ZB1GP | Zigbee Hub requiredCatalog noteZigbee 3.0 on a Tuya ZS2S module, works with any certified hub, no Tuya gateway needed | |
| Data Monitoring | ||
YesCatalog noteEnergy data and electricity bills export to a spreadsheet, from the app and from the local console | Not recorded | |
1 yearCatalog noteUp to one year of energy data, and going offline does not interrupt the recording | Not applicable / unspecifiedCatalog noteAccumulated, hourly, daily and monthly totals, history lives in the hub | |
YesCatalog noteCustom currency and electricity rate, with the bill broken down in charts | Not recorded | |
| Not recorded | 1 sCatalog noteReporting interval adjustable per value, 30 seconds by default | |
YesCatalog noteFixed or time-of-use pricing, with consumption shown per rate band | Not recorded | |
YesCatalog noteOvercurrent, overpower, overvoltage and undervoltage thresholds, plus a run completion alert and a maintenance reminder based on accumulated runtime | Not recorded | |
| Features | ||
YesCatalog noteQuick Scenes in eWeLink, and its readings drive automations in Home Assistant | YesCatalog noteThrough the Zigbee hub or Home Assistant, not the device itself | |
NoCatalog noteWith no relay it can raise a threshold alert but cannot shed the load itself | No | |
NoCatalog noteSONOFF states this is a non-switch product that cannot control the load it measures | No | |
| Installation | ||
YesCatalog noteWires into live and neutral behind a socket or inside a junction box, and SONOFF recommends a wall box at least 60 mm deep | Yes | |
NoCatalog noteIndoor flush mounting only, with no rail clip | NoCatalog note18 mm wide body that sits above or below the circuit breakers without taking a DIN module | |
| Mains (100-240 V) | Mains (110-240 V) | |
| No | No | |
| Integrations | ||
YesCatalog noteReached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model | NoCatalog noteAlexa has no energy meter device type and this meter has no relay to expose as a switch, so a skill has nothing to publish | |
Upcoming platform supportCatalog noteThe meter is a Matter over Wi-Fi device, but SONOFF's own platform table marks Apple Home as not yet able to add it: the Home app still does not accept the Matter energy meter device type. Nothing on SONOFF's side is missing, so the meter gets in once Apple supports that type. | No | |
YesCatalog noteReached by adding the meter to eWeLink and linking the account, the path SONOFF documents for this model | Not recorded | |
YesCatalog noteSONOFF's platform table gives Home Assistant two routes, Matter and MQTT discovery, and both carry the voltage, current, power and energy readings | YesManufacturer sourceHome Assistant use through Zigbee2MQTT is documented. Zemismart SPM01 manufacturer product page →
A compatible Zigbee coordinator and integration are required. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteVia Zigbee2MQTT or ZHA | |
YesCatalog noteMatter over Wi-Fi: the device carries a Matter QR code and is commissioned by scanning it from a Matter app | Home Assistant is the one Matter controller that accepts it today, because the energy meter device type is not yet handled by the other ecosystems | No | |
YesCatalog noteReached through eWeLink account linking, and SONOFF notes SmartThings also reads the power consumption figures | YesCatalog notePairs with a SmartThings hub as a standard Zigbee 3.0 device | |
| Local Control | ||
YesCatalog noteJSON-RPC 2.0 over HTTP and WebSocket, documented as an open API | No | |
YesManufacturer sourceA local browser console is provided. Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
This product measures energy and does not switch the attached load. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteThe OpenEdge web console runs on the device and needs no app and no account | No | |
YesManufacturer sourceMQTT access is listed. Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
This product measures energy and does not switch the attached load. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteMQTT is configured from the device itself and is how Home Assistant reads the meter with no cloud in the path | NoCatalog noteNo native MQTT, though Zigbee2MQTT republishes the readings | |
| Metering | ||
| Not recorded | ±1%Catalog noteAccuracy Class 1 per IEC 61557-12 | |
YesManufacturer sourceBidirectional energy metering is supported. Sonoff MINI PM Matter Over WiFi Power Meter (Non-Switch) — manufacturer product description →
This product measures energy and does not switch the attached load. Document check only; not a hands-on test or verification of every regional or firmware variant. Catalog noteBi-directional metering separates what the load consumes from what a balcony solar array produces, which the app can record as a negative value | YesCatalog noteSeparate forward and reverse energy totals for solar | |
| Not applicable / unspecified | Not applicable / unspecified | |
Not applicable / unspecifiedCatalog noteInline measurement, no current transformer involved | Not applicable / unspecifiedCatalog noteInline measurement, the conductor is threaded through the body | |
| Not applicable / unspecified | Not applicable / unspecifiedCatalog noteRated up to 63 A without a current transformer | |
1Catalog noteOne circuit, the load wired through its L and L Out terminals | 1Manufacturer sourceThe meter monitors a single-phase circuit. Zemismart SPM01 manufacturer product page →
A compatible Zigbee coordinator and integration are required. Document check only; not a hands-on test or verification of every regional or firmware variant. | |
NoCatalog noteSONOFF documents real-time voltage, current, power and accumulated energy, with no power factor reading | YesCatalog noteVoltage, current, power, power factor and energy | |
NoCatalog noteRated 100-240V~ 50/60Hz on a single line, so a 120/240 V split-phase service is out of scope | No | |
| No | No | |
The table matches specifications by section and field. It preserves notes, separates missing data from explicit “No” values, and keeps qualifications attached to their values. No overall winner is assigned from feature counts.
Read our comparison methodology