The Smart Device Compare comparison

Shelly 1PM Mini Gen4 vs Sonoff MINI ONE PM Matter Over WiFi Smart Switch

Understand the differences. Decide what matters to your home.

Build another comparison →

Before you compare every specification

Key differences between Shelly 1PM Mini Gen4 and Sonoff MINI ONE PM Matter Over WiFi Smart Switch

A summary of selected recorded differences between these relays. Check the full specification table below for details and conditions.

Feature differences among your selected devices
  • Dry Contact Mode (features): Shelly 1PM Mini Gen4 — Yes; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — No (The manual's terminal table lists the two outputs as live wire output terminals, so the contact is not potential-free).
  • On Off Button (features): Shelly 1PM Mini Gen4 — No; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — Yes (A single press toggles the load; press and hold for pairing or factory reset).
  • Zigbee Router (features): Shelly 1PM Mini Gen4 — Yes; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — No.
  • Dc Power (power): Shelly 1PM Mini Gen4 — Yes; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — No (Mains AC only: the manual warns it is for single-phase 100-240V use).
Specifications to check side by side
  • Bluetooth (connectivity): Shelly 1PM Mini Gen4 — Yes (Functions as a Bluetooth gateway); Sonoff MINI ONE PM Matter Over WiFi Smart Switch — For Pairing (The manual's EU declaration of conformity lists BLE 2402-2480 MHz for this model, the transport Matter uses to commission a Wi-Fi device).
  • Zigbee (connectivity): Shelly 1PM Mini Gen4 — Zigbee Hub required; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — No.
  • Ac Load Voltage (power): Shelly 1PM Mini Gen4 — 110-240 V; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — 100-240V.
  • Resistive Maximum Load Current (power): Shelly 1PM Mini Gen4 — 8A; Sonoff MINI ONE PM Matter Over WiFi Smart Switch — 16A.
Information still to confirm
  • 13 of 46 comparison fields lack a resolved value for at least one selected device. Missing information is not evidence that a feature is absent.
  • Check the full table and manufacturer documentation before ruling out a device.

These observations are derived from recorded catalog data and have not all been independently verified. Confirm details with the manufacturer before purchasing.

Compare capabilities, compatibility and setup requirements.

What the catalog tells us

Understand the tradeoffs.

These counts describe the available data, not a quality score. More features do not automatically make a better device.

8differences with recorded values for every device
13rows with missing or unspecified information

Your priorities, side by side

Focus on what changes.

Mark the specifications you care about. Open manufacturer sources for verification scope; fields without citations remain catalog data. Expand notes for other qualifications.

Showing 46 of 46 rows. “Not recorded” does not mean “No”.

Connectivity

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

IEEE 802.11 b/g/n 2.4GHz

Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Shelly 1PM Mini Gen4
Yes
Catalog note

Functions as a Bluetooth gateway

Sonoff MINI ONE PM Matter Over WiFi Smart Switch
For Pairing
Catalog note

The manual's EU declaration of conformity lists BLE 2402-2480 MHz for this model, the transport Matter uses to commission a Wi-Fi device

Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Shelly 1PM Mini Gen4
Zigbee Hub required
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No

Features

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Smart timers and scenes in eWeLink, plus HTTP, WebSocket and MQTT hooks for Home Assistant, OpenHAB, ioBroker and Node-RED

Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Catalog note

Indoor concealed installation: it mounts inside an electrical box

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Catalog note

The manual's terminal table lists the two outputs as live wire output terminals, so the contact is not potential-free

Shelly 1PM Mini Gen4
Yes
Catalog note

Power metering

Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Manufacturer source

The switch measures energy in both directions.

Sonoff MINI ONE PM Matter Over WiFi Smart Switch manufacturer product page →
Source section
Product description
Model
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Region
Manufacturer product page; no universal regional compatibility implied
Firmware
Not specified by this source
Checked

Observe installation and load-type restrictions.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

Bidirectional metering, so it reads solar generation as well as consumption, with a year of local data storage

Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Shelly 1PM Mini Gen4
No
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

A single press toggles the load; press and hold for pairing or factory reset

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

SONOFF's MINI-1GSP knowledge center documents OTA firmware updates, including over MQTT from Home Assistant

Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Shelly 1PM Mini Gen4
1
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
1
Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

L Out carries the switched live wire to the load

Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Detached relay mode turns the wired wall switch into a smart trigger

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No

Integrations

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Via Matter

Shelly 1PM Mini Gen4
Yes
Catalog note

Via Matter

Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Via Matter

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Via Matter

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Two paths: the manual documents adding it to Home Assistant via Matter, and SONOFF exposes local HTTP (JSON-RPC), WebSocket and MQTT APIs for it

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Manufacturer source

Matter compatibility is specified.

Sonoff MINI ONE PM Matter Over WiFi Smart Switch manufacturer product page →
Source section
Product description
Model
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Region
Manufacturer product page; no universal regional compatibility implied
Firmware
Not specified by this source
Checked

Observe installation and load-type restrictions.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

Matter over Wi-Fi, the protocol the product is named for

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Via Matter

Power

Shelly 1PM Mini Gen4
110-240 V
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
100-240V
Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

Rated 16A 100-240V~ 50/60Hz, single-phase only

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
12V / 24-48V
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not applicable / unspecified
Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not applicable / unspecified
Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not applicable / unspecified
Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
No
Catalog note

Mains AC only: the manual warns it is for single-phase 100-240V use

Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
Yes
Catalog note

LED drivers, transformers, fans, refrigerators and air conditioners

Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded
Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

SONOFF's product FAQ answers that the MINI-1GSP does require a neutral wire

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

The official rating states 16A max resistive load

Shelly 1PM Mini Gen4
8A
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
16A
Manufacturer source

The stated maximum load current is 16 A.

Sonoff MINI ONE PM Matter Over WiFi Smart Switch manufacturer product page →
Source section
Product description
Model
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Region
Manufacturer product page; no universal regional compatibility implied
Firmware
Not specified by this source
Checked

Observe installation and load-type restrictions.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Shelly 1PM Mini Gen4
Not recorded
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Not recorded

Safety Features

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Catalog note

The relay cuts power when current, voltage, power or temperature passes its safe limit

Shelly 1PM Mini Gen4
Yes
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Yes
Specifications for Shelly 1PM Mini Gen4 versus Sonoff MINI ONE PM Matter Over WiFi Smart Switch
SpecificationShelly 1PM Mini Gen4Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Connectivity
YesYes
Catalog note

IEEE 802.11 b/g/n 2.4GHz

NoNo
Yes
Catalog note

Functions as a Bluetooth gateway

For Pairing
Catalog note

The manual's EU declaration of conformity lists BLE 2402-2480 MHz for this model, the transport Matter uses to commission a Wi-Fi device

NoNo
NoNo
NoNo
Zigbee Hub requiredNo
Features
YesYes
Catalog note

Smart timers and scenes in eWeLink, plus HTTP, WebSocket and MQTT hooks for Home Assistant, OpenHAB, ioBroker and Node-RED

NoNo
Catalog note

Indoor concealed installation: it mounts inside an electrical box

YesNo
Catalog note

The manual's terminal table lists the two outputs as live wire output terminals, so the contact is not potential-free

Yes
Catalog note

Power metering

Yes
Manufacturer source

The switch measures energy in both directions.

Sonoff MINI ONE PM Matter Over WiFi Smart Switch manufacturer product page →
Source section
Product description
Model
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Region
Manufacturer product page; no universal regional compatibility implied
Firmware
Not specified by this source
Checked

Observe installation and load-type restrictions.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

Bidirectional metering, so it reads solar generation as well as consumption, with a year of local data storage

NoNo
NoYes
Catalog note

A single press toggles the load; press and hold for pairing or factory reset

YesYes
Catalog note

SONOFF's MINI-1GSP knowledge center documents OTA firmware updates, including over MQTT from Home Assistant

Not recordedYes
11
YesYes
Catalog note

L Out carries the switched live wire to the load

Not recordedYes
Catalog note

Detached relay mode turns the wired wall switch into a smart trigger

YesNo
Integrations
YesYes
Catalog note

Via Matter

Yes
Catalog note

Via Matter

Yes
Catalog note

Via Matter

YesYes
Catalog note

Via Matter

YesYes
Catalog note

Two paths: the manual documents adding it to Home Assistant via Matter, and SONOFF exposes local HTTP (JSON-RPC), WebSocket and MQTT APIs for it

YesYes
Manufacturer source

Matter compatibility is specified.

Sonoff MINI ONE PM Matter Over WiFi Smart Switch manufacturer product page →
Source section
Product description
Model
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Region
Manufacturer product page; no universal regional compatibility implied
Firmware
Not specified by this source
Checked

Observe installation and load-type restrictions.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Catalog note

Matter over Wi-Fi, the protocol the product is named for

YesYes
Catalog note

Via Matter

Power
110-240 V100-240V
YesYes
Catalog note

Rated 16A 100-240V~ 50/60Hz, single-phase only

YesNot recorded
Not recordedNot recorded
Not recordedNot recorded
12V / 24-48VNot applicable / unspecified
Not recordedNot applicable / unspecified
Not recordedNot applicable / unspecified
YesNo
Catalog note

Mains AC only: the manual warns it is for single-phase 100-240V use

Not recordedNot recorded
Yes
Catalog note

LED drivers, transformers, fans, refrigerators and air conditioners

Not recorded
Not recordedNot recorded
Not recordedNot recorded
YesYes
Catalog note

SONOFF's product FAQ answers that the MINI-1GSP does require a neutral wire

YesYes
Catalog note

The official rating states 16A max resistive load

8A16A
Manufacturer source

The stated maximum load current is 16 A.

Sonoff MINI ONE PM Matter Over WiFi Smart Switch manufacturer product page →
Source section
Product description
Model
Sonoff MINI ONE PM Matter Over WiFi Smart Switch
Region
Manufacturer product page; no universal regional compatibility implied
Firmware
Not specified by this source
Checked

Observe installation and load-type restrictions.

Document check only; not a hands-on test or verification of every regional or firmware variant.

Not recordedNot recorded
Safety Features
YesYes
YesYes
YesYes
Catalog note

The relay cuts power when current, voltage, power or temperature passes its safe limit

YesYes

Know what’s behind the comparison.

The table matches specifications by section and field. It preserves notes, separates missing data from explicit “No” values, and keeps qualifications attached to their values. No overall winner is assigned from feature counts.

Read our comparison methodology